Skip to main content Skip to search Skip to main navigation
Menu

CHROMABOND® HR-X

Description
Spherical, hydrophobic polystyrene-divinylbenzene resin for SPE
Hydrophobic polystyrene-divinylbenzene copolymer pH stability 1 to14. High-purity material with highest reproducibility and lowest blank values due to a novel manufacturing process, spherical particles 85mm; pore size 55 to 60Å. Very high surface 1000m²/g; capacity 390mg/g (caffeine in water). Excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimised pore structure.

Recommended applications: pharmaceuticals/active ingredients from tablets, creams and water/waste water, drugs and pharmaceuticals from urine, blood, serum and plasma trace analysis of pesticides.


Cartridges in further sizes and phases of the HR-X poduct range available on request.
Properties
Base material: PS/DVB copolymer
Endcapped: No
Filter element material: PE
Manufacturer Article Number: 730937
Package: 30 pcs
Package capacity: 30 pcs
Particle size: 85 µm
Particle type: Fully porous
pH stability: 1 ... 14
Skip product gallery

Other customers also bought

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
CHROMABOND® HR-X, MPS column
Tubular syringe-shaped SPE column - already equipped with special cap and cannula to be used in Gerstel MultiPurposeSampler (MPS).Spherical, hydrophobic polystyrene-divinylbenzene resin for SPEHydrophobic polystyrene-divinylbenzene copolymer pH stability 1 to14. High-purity material with highest reproducibility and lowest blank values due to a novel manufacturing process, spherical particles 85mm; pore size 55 to 60Å. Very high surface 1000m²/g; capacity 390mg/g (caffeine in water). Excellent recovery rates especially for the enrichment of pharmaceuticals/active ingredients due to the spherical structure of the particles, very homogeneous surface, and optimised pore structure.Recommended applications: pharmaceuticals/active ingredients from tablets, creams and water/waste water, drugs and pharmaceuticals from urine, blood, serum and plasma trace analysis of pesticides.Cartridges in further sizes and phases of the HR-X poduct range available on request.
From CHF 210.10*
Skip product gallery

Similar products

CHROMABOND® SiOH-H2SO4/SA
Combination phase for SPE analysis of PCBsH2SO4: H2SO4-impregnated silica phase for oxidation of accompanying compounds to ionic and/or polar compounds.SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification for removal of ionic and sulphur-containing compounds.Recommended application: extraction of PCBs from oil with reference to German industrial standard DIN 51527, part 1. This combination column is used together with a SiOH column.
From CHF 471.60*

CHROMABOND® vacuum manifolds and accessories
For simultaneous preparation of up to 12 or 24 samples, replacement parts and accessories for special applications.Vacuum manifold complete consists of: glass cabinet with lid and lid gasket, removable needles on lower side of lid, vacuum gauge, control valve, valves and caps, variable rack.
From CHF 57.40*

CHROMABOND® Na2SO4/Florisil®
Combination phase for SPE of hydrocarbons from water acc. to DIN H53 / ISO DIS 9377-4Special combination phase of sodium sulphate and Florisil®.Recommended application: hydrocarbons from drinking, surface and waste waters.
From CHF 268.60*

CHROMABOND® QuEChERS extraction buffer mixes / clean-up mixes
QuEChERS method and pre-mixesWithin a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.Standard clean-up of food samples10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS.Extraction mixtures for sample preparation for determination of pesticides in food samples.MACHEREY-NAGEL offers a number of individually weighed and pre-mixed buffers and extraction mixtures, specially composed for different sample matrices.Mix I and Mix II are extraction mixtures, Mix III to Mix VI are clean-up mixtures.The food samples will be extracted with either Mix I or Mix II.Afterwards they will be purified with one of the following mixtures:Mix III (samples with low fat content; e.g. apples, strawberries),Mix IV (moderate content of chlorophyll and carotinoids; e. g. carrots, lettuce),Mix V (high content of chlorophyll and carotinoids; e. g. bell peppers, spinach),Mix VI (high fat content; e. g. avocados).Every mix is prepacked in a 15 ml centrifuge tube. Pack of 50 pieces.
From CHF 191.40*

CHROMABOND® NAN
Special phase for SPE analysis of PCB from sludgeSpecial combination phase:N: sodium sulphate for removal of trace water.A: SiOH/AgNO3 phase for removal of sulphur, sulphur-containing and polar compounds.Recommended application: extraction of PCB from sludge.
From CHF 501.80*

CHROMABOND® Na2SO4/Florisil®, glass columns
Combination phase for SPE of hydrocarbons from water acc. to DIN H53 / ISO DIS 9377-4Special combination phase of sodium sulphate and Florisil®.Recommended application: hydrocarbons from drinking, surface and waste waters.
From CHF 319.00*

CHROMABOND® SA/SiOH
Combination phase for SPE analysis of PCBSpecial combination phase:SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification.SiOH: unmodified silica for removal of polar compounds.Recommended application: extraction of PCB from waste oil (hexane extract).
From CHF 388.00*

CHROMABOND® Kombi-Kit PCB for solid phase extraction (SPE)
This CHROMABOND® Combi-Kit PCB is used for the SPE enrichment of polychlorinated biphenyls from oil.
From CHF 353.30*

CHROMABOND® XTR
Kieselguhr phase for liquid-liquid extractionBase material coarse-grained kieselguhr, large pore size, high pore volume, constantly high batch-to-batch quality, pH working range 1 to 13.Application: liquid-liquid extraction of highly viscous aqueous solutions such as physiological fluids (blood, plasma, and serum) in clinical chemistry, dyes in textiles, environmental and food analysis.Glass columns availlable on request.
From CHF 123.10*