Skip to main content Skip to search Skip to main navigation
Menu

CHROMABOND® QuEChERS extraction buffer mixes / clean-up mixes

Description
QuEChERS method and pre-mixes
Within a few years after its devleopment by Anastassiades et al. the QuEChERS method has gained a leading position for determination of pesticide residues in food by GC-MS or LC-MS allowing rapid and cheap clean-up of strong matrix-contaminated samples.
Standard clean-up of food samples
10 g sample are homogenised with 10 ml acetonitrile. After adding the internal standard the sample is shaken with 4 g MgSO4 and 1 g NaCI and afterwards centrifuged. 1 ml of the supernantant is spiked with 25 mg CHROMABOND® Diamino and 150 mg MgSO4 and shaken again. After centrifugation the supernatant is injected into the GC/MS.

Extraction mixtures for sample preparation for determination of pesticides in food samples.

MACHEREY-NAGEL offers a number of individually weighed and pre-mixed buffers and extraction mixtures, specially composed for different sample matrices.
Mix I and Mix II are extraction mixtures, Mix III to Mix VI are clean-up mixtures.

The food samples will be extracted with either Mix I or Mix II.
Afterwards they will be purified with one of the following mixtures:
  • Mix III (samples with low fat content; e.g. apples, strawberries),
  • Mix IV (moderate content of chlorophyll and carotinoids; e. g. carrots, lettuce),
  • Mix V (high content of chlorophyll and carotinoids; e. g. bell peppers, spinach),
  • Mix VI (high fat content; e. g. avocados).

Every mix is prepacked in a 15 ml centrifuge tube. Pack of 50 pieces.

Properties
Composition: 0.15g CHROMABOND® Diaminowith 0.9g MgSO4and 45mg Carbon
Description: Mix V Diamino/Carbon Clean-up Mix
Manufacturer Article Number: 730975
Volume column: 15 ml
Skip product gallery

Similar products

CHROMAFIX® PS
The innovative cation exchanger offers:mixed-mode SPE phase with distinct cation exchange and RP properties excellent enrichment of basic analytesmodern support polymer with optimised pore structure and large specific surfacegood reproducibility, reliable and cost-efficient analysesmore aggressive washing procedures for matrix removal possiblecleaner samples and protection of analytical HPLC and GC instrumentationquantificationof analytes from heavily contaminated sampleslower limits of detection also for critical matrices... the perfect fit for basic analytes in comination with CHROMABOND® HR-X
From CHF 363.10*

Empty columns CHROMABOND®, PP
Empty CHROMABOND® column (PP) for SPE, one PE-filter element is already inserted in the column.
From CHF 104.10*

CHROMABOND® SiOH
Unmodified silica phase for SPEUnmodified, weakly acidic silica, pore size 60Å, particle size 45µm, specific surface 500m²/g, pH stability 2 to 8, very polar, adsorbs humidity from air, for this reason it should be kept well closed and if necessary dried before use due to its high affinity for polar compounds it should not be conditioned with polar (e.g. methanol) or water-containing solvents.Recommended applications: aflatoxins, chloramphenicol, pesticides, steroids, vitamins.
From CHF 138.00*

CHROMABOND® PA
Polyamide 6 for SPEMatrix polyamide 6, unmodified, high purity, particle size 40 to 80µm.Recommended application: flavonoids, PAH.
From CHF 197.60*

CHROMABOND® SA/SiOH
Combination phase for SPE analysis of PCBSpecial combination phase:SA: strongly acidic cation exchanger based on silica with benzenesulphonic acid modification.SiOH: unmodified silica for removal of polar compounds.Recommended application: extraction of PCB from waste oil (hexane extract).
From CHF 388.00*

CHROMABOND® Kombi-Kit PCB for solid phase extraction (SPE)
This CHROMABOND® Combi-Kit PCB is used for the SPE enrichment of polychlorinated biphenyls from oil.
From CHF 353.30*

CHROMAFIX® C18
Octadecyl modified silica phase for SPE, not endcappedBase material silica, pore size 60 Å, particle size 45 µm for C18, specific surface 500 m²/g, pH stability 2 to 8 octadecyl phases, not endcapped, carbon content 14 % possesses more free silanols (SiOH), which allow secondary interactions with polar groups of the analytes.Recommended applications: non-polar compounds, pesticides.
From CHF 298.90*