Skip to main content Skip to search Skip to main navigation
Menu

Capillary columns BP624

Description
Cyanopropylphenyl Polysiloxane. For the analysis of volatile components of drinking water, chlorinated hydrocarbons, solvents and for the EPA method 624, USP G43 methods, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-624, OV-624, AT-624, HP-VOC, CP-Select624CB, 007-624, Rtx-Volatiles, VOCOL, ZB-624.

Properties
Film thickness: 1.8 µm
Int. Ø: 0.32 mm
Length: 30 m
Manufacturer Article Number: 054832
Max. temperature programme: 240 °C
Temperature max isotherm: 230 °C
UNSPSC: 41-12-17-09
USP listing: G43
Skip product gallery

Similar products

OPTIMA® 5 capillary columns for GC
5% phenyl - 95% dimethylpolysiloxane USP G27, G36 nonpaolar standard phase with large range of application similar phases: Permabond® SE-52 , SE-54, SE-52, DB-5, HP-5, SPB-5, CP-Sil 8, Rtx-5, 007-5, BP5, MDN-5, AT-5, ZB-5 for columns with 0.1 to 0.32mm ID and films
From CHF 436.80*

OPTIMA® 1 high performance capillary columns for GC
100% dimethylpolysiloxanenonpolar phase separation of components according to boiling points thick film columns ≥3µm film are especially recommended for solvent analysis.Similar phases: Permabond® SE-30, OV-1, DB-1, SE-30, HP-1, SPB-1, CP-Sil 5 CB, Rtx-1, 007-1, BP1, MDN-1, AT-1, ZB-1, OV-101.For columns with 0.25 to 0.32mm ID and films
From CHF 782.10*

Optima® WAX capillary columns for GC
polyethylene glycol 20000 daltonsUSP G16polar phaserecommended for solvent analysis and alcoholssuitable for aqueous solutionssimilar phases: Premabond® CW 20 M , DB-Wax, Supelcowax, HP-Wax, HP-INNOWAX, Rtx-Wax, CP-Wax 52 CB, Stabilwax, 007-CW, BP20, AT-Wax, ZB-WaxMax. temperature for isothermal operation 240°C, max. temperature for short isotherms in a temperature programme: 250°C,for 0.53 mm ID columns the max. temperatures are 220 and 240°C, resp.Custom-made columns to your specifications available on request.Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules.Column ends are melted or closed with septa. Additionally, we supply the corresponding test mixture with each column.
From CHF 782.10*

Capillary columns GC BP21
Nitroterephtalic acid modified PEG. For low molecular weight acids, alcohols, aldehydes, acrylates and ketones. Suitable replacement for: DB-FFAP, HP-FFAP, Stabilwax-DA, CPWax-58CB.Polar phaseAble to be solvent rinsed (water or methanol are not recommended for rinsing)
From CHF 1,078.00*

Capillary columns GC BP20
Polyethylene Glycol phase. GC column for analyses such as alcohol, free acids, fatty acid methyl esters, aromatics, solvents and essential oils. Suitable replacement for: Carbowax 20M, CP-Wax 52 CB, DB-WAX, Elite-WAX, HP-20M, HP-INNOWax RH-WAX, Rtx-Wax, Stabilwax, SUPELCOWAX 10, TG-WaxMS, VF-WAXms, ZB-WAX.Industry standard wax columnPolar phase
From CHF 617.00*

Capillary columns GC BPX5
5% Phenyl Polysilphenylene-siloxane. General purpose GC column for routine gas chromatographic analysis. Suitable replacement for: DB-5, DB-5ms, DB-5.625, XTI-5, Rtx-5ms, Ultra-2, HP-5, HP-5MS, HP5-TA, SPB-5, MDN-5S, CP-Sil8CB, Rxt-Sil 5MS, AT-5ms, VB-5, ZB-5, VF-5ms.Very low bleedNon-polarExtremely inert
From CHF 556.00*

Capillary columns GC BP5
5% Phenyl / 95% Dimethyl Polysiloxane. Low bleed. General purpose GC column for all routine analyses such as aromatics, pesticides, herbicides, hydrocarbons. Suitable replacement for: DB-5, Rtx-5, HP-5, Ultra-2, PTE-5, SPB-5, MDN-5, CP-Sil 8CB, VB-5, ZB-5, VF-5ms.
From CHF 523.00*

Capillary columns BPX-Volatiles
Cyanopropyl Polysilphenylene. Polar phase. For environmental analyses, volatile organic substances, alcohol analyses and for the EPA method 624, USP G43 methods, 502.2, SW-846 and 8240 / 8260 methods. Suitable replacement for: DB-VRX, HP-624, OPTIMA 624, ELITE-624, 007-624, RTXVOLATILES, SPB-624, TRV1, CPSIL 13 CB, VOCOL, VB-624, CP-624.
From CHF 1,130.00*

Capillary columns HT5
5% Phenyl Polycarborane siloxane. Ultra-high temperature columns for simulated distillation applications, general hydrocarbon profiles, pesticides, herbicides and for GCMS applications.
From CHF 650.00*

Capillary, phenyl deactivated fused silica
Coated fused silica tubing for GC capillary applications.High homogeneityChemically inertStandard polyimide temperature resistance up to 380 °CPolyimide coating is chemically resistantLow dielectric constant, low dielectric lossImpermeable to all gases (except H2, He)Free of thermal hysteresisHigh intrinsic tensile strengthVery low thermal expansionUse with hydrofluoric acid, phosphoric acid, alkalis and alkali metal-containing compounds should be avoided, as this can lead to dissolution of the quartz glass and devitrification of the surface.
From CHF 193.00*