Skip to main content Skip to search Skip to main navigation
Menu

EC analytical columns NUCLEODUR® 100-5 CN-RP, 5 µm

Description
  • Pore size 110 Å, - USP L10

  • Multi-mode columns (RP and NP)

  • Widens the scope in selectivity

  • Differnet retention characteristics compared to C8 and C18

  • Stable against hydrolysis at low pH values, working range pH 1-8

  • High reproducibility from lot to lot

  • Ideal for: tricyclic antidepressants, steroids, organic acids

Eluent in column acetonitrile, particle size 5 µm

Properties
Carbon content: 7.0 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 4.0 mm
Length: 125 mm
Manufacturer Article Number: 760153.40
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
USP listing: L10
Volume column: 1.56 ml
pH stability: 1 ... 8
Skip product gallery

Similar products

HPLC Detector lamps
From CHF 635.00*

Guard columns for NUCLEOCEL DELTA, 10µm
NUCLEOCEL DELTA enantiomer separation based on cellulose derivativesbase material silica, chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40similar phases: Chiralcel® OD, Kromasil®, CelluCoat™, Eurocel® 01standard particle size 10µmS-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi)NUCLEOCEL DELTA for normal phase applications: eluent in column n-heptane - propanol-2 (90:10, v/v)typical eluents are heptane - propanol mixturesNUCLEOCEL DELTA-RP for reversed phase applications: eluent in column acetonitrile - water (40:60), v/v)designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchloraterecommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.
Price on request

Guard columns for NUCLEOCEL DELTA-RP, 10µm
NUCLEOCEL DELTA enantiomer separation based on cellulose derivativesbase material silica, chiral selector Cellulosetris-(3,5-dimethylphenylcarbamate) - USP L40similar phases: Chiralcel® OD, Kromasil®, CelluCoat™, Eurocel® 01standard particle size 10µmS-Type for high resolution, allows use of shorter columns (150 mm) for faster separations, pressure stability up to ~ 150 bar (2000 psi)NUCLEOCEL DELTA for normal phase applications: eluent in column n-heptane - propanol-2 (90:10, v/v)typical eluents are heptane - propanol mixturesNUCLEOCEL DELTA-RP for reversed phase applications: eluent in column acetonitrile - water (40:60), v/v)designed for use either in polar organic mode or with eluents containing high concentrations of chaotropic salts such as perchloraterecommended applications: pharmaceutically active compounds, chiral pollutants (e. g. herbicides, PCB), chiral compounds in food (dyes, preservatives), chiral catalysts and bioorganic compounds.
Price on request

EC analytical HPLC columns, NUCLEODUR PFAS Delay
NUCLEODUR PFAS Delay columns trap and therefore delay system-related PFAS contaminants, ensuring trace level analysis of PFAS in your samples. This HPLC phase is made of high purity NUCLEODUR HPLC silica gel and is extensively endcapped. Due to a low bleeding characteristics these columns are suitable for high sensitivity LC/MS analysis.
From CHF 960.00*

Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Price on request

EC analytical columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 439.40*

EC analytical columns NUCLEODUR® 100-5 CN, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 NH2, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 NH2-RP, 5 µm
Pore size 110 Å, particle sizes 3 and 5 µm; 2.5 % C; not endcapped - USP L8Multi-mode columns (RP and NP):Normal phase chromatography (NP) with hexan, dichloromethane or 2-propanol as mobile phase for polar compounds such as substituted anilines, esters, chlorinated pesticidesReversed phase chromatography (RP) of polar compounds like sugars in aqueous-organic eluent systemsIon exchange chromatography of anions and organic acids using common buffers and organic modifiersstable against hydrolysis at low pH, working range pH 2-8, 100 % stable in water, suitable for LC-MSIdeal for:polar compounds under RP conditions (sugars, DNA bases), hydrocarbons under NP conditionsEluent in column is n-heptane for the NP mode - RP columns are delivered in acetonitrile - water. For changing the solvent system a rinsing step with THF may be necessary.Eluent in column acetonitrile, particle size 5 µm.
From CHF 415.40*

VarioPrep preparative columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 1,206.40*