EC analytical columns NUCLEODUR® C18 Gravity, 5 µm

Description
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phases

Available as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.

  • Ideal for method development

  • Allows HPLC at pH extremes (pH 1 - 11)

  • Suitable for LC/MS due to low bleeding characteristics

  • Recommended for overall sophisticated analytical separations

  • Optimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressants

Particle size 5 µm, 18 % C

Properties
Carbon content: 18 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 4.0 mm
Length: 50 mm
Manufacturer Article Number: 760102.40
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 0.62 ml
pH stability: 1 ... 11
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
Guard columns for EC columns NUCLEODUR® C18Gravity, 5µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesavailable as octadecyl (C18 -USP L!) and octyl (C8 - USP L7) modificationsPore size 110 Å; particle sizes 1,8µm, 3µm and 5µm for C18, 1,8 and 5µm for C87, 10, 12 and 16µm particles for preparative separations on requestcarbon content 18 %C for C18 , 11%C for C8ideal for method developmentallows HPLC at pH extremes (pH 1 - 11)suitable for LC/MS due to low bleeding characteristicsrecommended for overall sophisticated analytical separationsoptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants; herbicides; phytopharmaceuticals; immunosppressantsGuard columns for EC columns require guard column adapter EC (Cat. No. 7.081 898)
Price on request
Skip product gallery

Similar products

Guard columns for EC columns NUCLEODUR® C18 Isis, 3 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC.
From CHF 241.30*

Guard columns for NUCLEOGEL® SUGAR 810 Ca columns
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
From CHF 709.00*

Guard columns for NUCLEOGEL® SUGAR 810 H columns
Sulphonated polystyrene/divinylbenzene resins in diffent ionic forms and RP chromatographySeparation mechanism includes ion exclusion, ion exchange, size exclusion, ligand exchange as well as NP and RP chromatographyThis guard columns require the CC column holder 30 mm.
From CHF 709.00*

VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10 C18 ec
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.VarioPrep guard columns require a VP guard column holder.
From CHF 522.10*

VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsVarioPrep guard columns require a VP guard column holder.
From CHF 449.30*

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 297.30*

VarioPrep preparative columns NUCLEDUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 765.40*

EC analytical columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 439.40*

EC analytical columns NUCLEODUR® 100-5 CN, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column n-heptane, particle size 5 µm.
From CHF 415.40*