Skip to main content Skip to search Skip to main navigation
Menu

EC analytical columns NUCLEODUR® C18 Isis, 3 µm

Description
C18 phase with special polymeric, crosslinked surface modification - USP L1
  • Pore size 110 Å

  • High steric selectivity

  • Outstanding surface deactivation

  • Suitable for LC/MS due low bleeding characteristics

  • pH stability 1 - 10

  • Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitamins

Particle size 3 µm, 20 % C

Properties
Carbon content: 20 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 3.0 mm
Length: 50 mm
Manufacturer Article Number: 760400.30
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 3 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 0.35 ml
pH stability: 1 ... 10
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
Guard columns for EC columns NUCLEODUR® C18 Isis, 3 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsGuard columns for EC columns require the guard column adapter EC.
From CHF 241.30*
Skip product gallery

Similar products

EC analytical columns NUCLEODUR® 100-5 C18 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 5 µm.
From CHF 297.30*

HPLC Detector lamps
From CHF 635.00*

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

EC analytical columns NUCLEODUR® C18 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 18 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 3 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 3 µm, 18 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 18 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® 100-5 CN, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 CN-RP, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column acetonitrile, particle size 5 µm
From CHF 415.40*

EC analytical columns NUCLEODUR® C18 Pyramid, 5 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 5 µm, 14 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® C18 Pyramid, 3 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 3 µm, 14 % C
From CHF 750.90*