Skip to main content Skip to search Skip to main navigation
Menu

EC analytical columns NUCLEODUR® C18 Pyramid, 5 µm

Description
  • Stable in 100 % aqueous eluent systems- USP L1

  • Pore size 110 Å

  • Interesting polar selectivity features

  • Excellent base deactivation; suitable for LC/MS due low bleeding characteristics

  • pH stability 1 - 9

  • Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acids

Particle size 5 µm, 14 % C

Properties
Carbon content: 14 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 2.0 mm
Length: 50 mm
Manufacturer Article Number: 760200.20
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 0.15 ml
pH stability: 1 ... 9
Skip product gallery

Similar products

EC analytical columns NUCLEODUR® 100-5 C18 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 5 µm.
From CHF 297.30*

EC analytical columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 439.40*

EC analytical columns NUCLEODUR® 100-3 C18 ec, 3 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 3 µm.
From CHF 465.50*

EC analytical columns NUCLEODUR® C18 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 18 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 3 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 3 µm, 18 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 18 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® 100-5 CN, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column n-heptane, particle size 5 µm.
From CHF 415.40*

EC analytical columns NUCLEODUR® 100-5 CN-RP, 5 µm
Pore size 110 Å, - USP L10Multi-mode columns (RP and NP)Widens the scope in selectivityDiffernet retention characteristics compared to C8 and C18Stable against hydrolysis at low pH values, working range pH 1-8High reproducibility from lot to lotIdeal for: tricyclic antidepressants, steroids, organic acidsEluent in column acetonitrile, particle size 5 µm
From CHF 415.40*

Accessories and replacement parts for EC columns
Analytical column system manufactured from stainless steel M 8 outer threads on both ends combination of sealing element and very fine-meshed stainless steel screen, PTFE sealing ring and fitting adaptor column heads SW 12 with inner threads M8 x 0,75 and UNF 10-32, as built -in guard columns use ChromCart® guard column cartridges with 8mm length with the guard column adaptor EC, packed with NUCLEODUR® spherical silica.
From CHF 46.10*

EC analytical columns NUCLEOSIL® 100-5 C18 PAH, 5 µm
Special octadecyl phase for PAH analysis.Base material NUCLEOSIL® silica, particle size 5 µm, pore size 100 Å; polymeric coating - USP L1; eluent in column acetonitrile/water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA.Detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection).Guard columns for EC columns NUCLEOSIL® 100-5 C18 PAH, 5 µm available on request.
From CHF 962.00*