Description
Special octadecyl phase for PAH analysis.

Base material NUCLEOSIL® silica, particle size 5 µm, pore size 100 Å; polymeric coating - USP L1; eluent in column acetonitrile/water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA.

Detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection).

Guard columns for EC columns NUCLEOSIL® 100-5 C18 PAH, 5 µm available on request.

Properties
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 4.6 mm
Length: 250 mm
Manufacturer Article Number: 720117.46
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Analytical
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L118
Volume column: 4.15 ml
pH stability: 2 ... 8
Skip product gallery

Similar products

EC analytical columns NUCLEODUR® C18 Isis, 5 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 5 µm, 20 % C
From CHF 604.80*

EC analytical columns NUCLEODUR® 100-5 C18 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 5 µm.
From CHF 297.30*

HPLC Detector lamps
From CHF 635.00*

VarioPrep preparative columns NUCLEODUR® C18 Pyramid
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 5 µm, 14 % C
Price on request

VarioPrep columns for preparative HPLC NUCLEODUR® Sphinx RP, 5 µm
Distinct selectivity based on bifunctional surface coverage - USP L1 and USP L11Pore size 110 ÅHigh density of covalently bonded silanes for tailing-free peaks widens the scope for method developmentpH stability 1 - 10Suitable for LC/MS due low bleeding characteristicsHigh reproducibility and consistent quality due to tight QC proceduresRange of application: quinolone antibiotics, sulfonamides, xanthines, substituted aromaticsVarioPrep guard columns require a VP guard column holder.
From CHF 449.30*

VarioPrep preparative columns NUCLEODUR® C18 Isis
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 5 µm, 20 % C
From CHF 2,448.20*

EC analytical columns NUCLEODUR® C18 Pyramid, 1.8 µm
Stable in 100 % aqueous eluent systems- USP L1Pore size 110 ÅInteresting polar selectivity featuresExcellent base deactivation; suitable for LC/MS due low bleeding characteristicspH stability 1 - 9Ideal for: analgesics, penicillin antibiotics, nucleic acid bases, water-soluble vitamins, complexing agetns, organic acidsParticle size 1.8 µm, 14 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Isis, 3 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 3 µm, 20 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Isis, 1.8 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 1.8 µm, 20 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® 100-5 C8 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octyl phases, 10.5 % C, particle size 5 µm.
From CHF 297.30*