OPTIMA® 5 MS Accent capillary columns for GC
 
                                        CHF 1,007.20*
									
						Content:
					
				
									
						1
						
					
				
							
			
	
                            Delivery according to order confirmation
                                        
                    Product number:
                
            
                                        
                
                        4003021
                
                    
    
                    
         
                        
                                    
                        Manufacturer:
                    
                
                                    
                                                    Macherey-Nagel GmbH & Co. KG
                                            
                            
            
    Packaging information:
                                    
                        Weight:
                    
                
                                    
                        0.028 kg
                    
                            
            
                         
                            
                                
                                            
                                            
                                            
                                            
                                            
                                            
                                            
                                            
                                            
                                            
                             
        
                
            
        Description
    
        
    
            
                        silarylene phase
Max. temperature for isothermal operation: 340 °C,
Max. temperature for short isotherms in a temperature programme: 360 °C
for cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °C
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.
Additionally, we supply the corresponding test mixture with each column.
                
                                        - With polarity similar to a 5 % diphenyl -95 % dimethylpolysiloxane phase.
- USP G27, G36
- Lowest column bleed, nonpolar phase, ideal for ion trap and quadrupol MS detectors solvent rinsing for removal of impurities applicable
- Application areas: all-round phase for environmental analyses, trace analyses, EPA methods, pesticides, PCB, food and drug analyses
Max. temperature for isothermal operation: 340 °C,
Max. temperature for short isotherms in a temperature programme: 360 °C
for cloumns with film thicknesses > 5.5 µm the max. temperatures are 320 and 340 °C
Each column is individually tested and supplied with test certificate and test chromatogram, but without fittings or ferrules. Column ends are melted or closed with septa, and thus protected from atmospheric oxygen.
Additionally, we supply the corresponding test mixture with each column.
                
            
        Properties
    
        
    
            | Film thickness: | 1.00 µm | 
|---|---|
| Int. Ø: | 0.25 mm | 
| Length: | 30 m | 
| Manufacturer Article Number: | 725826.30 | 
| Material column: | Quartz glass | 
| Max. temperature programme: | 340 °C | 
| Polarity: | Nonpolar | 
| Temperature max isotherm: | 320 °C | 
| USP listing: | G27, G36 | 
 
                                                                                                                                                                            
             
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                 
                                                                            
                                            
        
                                                                                