Skip to main content Skip to search Skip to main navigation
Menu

VarioPrep preparative columns NUCLEODUR® 100-5 C18 ec, 5 µm

Description
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.

Octadecyl phases, 17.5 % C. Particle size 5 µm.

Properties
Carbon content: 17.5 %
Eluent in column: Acetonitrile/water
Endcapped: Yes
Int. Ø: 10 mm
Length: 250 mm
Manufacturer Article Number: 762022.100
Material column: Stainless steel
Max. temperature resistance: 60 °C
Method: Preparative
Particle size: 5 µm
Particle type: Fully porous
Separation system: Reverse phase
USP listing: L1
Volume column: 20 ml
pH stability: 1 ... 9
Skip product gallery

Accessories

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep columns for preparative HPLC, NUCLEODUR® 100-5, 100-7, 100-10 C18 ec
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.VarioPrep guard columns require a VP guard column holder.
From CHF 522.10*

Macherey-Nagel GmbH & Co. KG

Macherey-Nagel GmbH & Co. KG
VarioPrep guard column holders and replacement parts
VarioPrep columnscolumn system for preparative HPLC manufactured from stainless steel with two adjustable end fittings, allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column, packed with NUCLEODUR® and NUCLEOSIL® spherical silica.O-rings available on request.
From CHF 354.60*
Skip product gallery

Similar products

Preparative HPLC columns Nucleosil®100-5 C18
Grain size 5 µm, pore dia. 100 Å. Octadecyl phase, endcapped, 15 % C.
From CHF 399.10*

EC analytical columns NUCLEODUR® 100-5 C18 ec, 5 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 5 µm.
From CHF 297.30*

EC analytical columns NUCLEOSIL® 100-5 C18 PAH, 5 µm
Special octadecyl phase for PAH analysis.Base material NUCLEOSIL® silica, particle size 5 µm, pore size 100 Å; polymeric coating - USP L1; eluent in column acetonitrile/water 70:30; allows efficient gradient separation of the 16 PAH in accordance with EPA.Detection of the separated PAH by UV (250 to 280 nm), with diode array or with fluorescence detection at different wavelegths for excitation and emission (acenaphthylene cannot be analysed with fluorescence detection).Guard columns for EC columns NUCLEOSIL® 100-5 C18 PAH, 5 µm available on request.
From CHF 962.00*

EC analytical columns NUCLEODUR® 100-3 C18 ec, 3 µm
Available with medium density octadecyl (C18 - USP L1) and octyl (C8 - USP L7) modification pore size 110 Å, particle sizes 3 µm and 5 µm; 7 µm, 10 µm, 12 µm, 16 µm, 20 µm, 30 µm und 50 µm for preparative separations on request for daily routine analysis and up-scaling for preparative HPLC, pH stability 1 - 9. Carbon content 17.5 % C for C18, 10.5 % C for C8, high reproducibility from lot to lot for standard routine applications in reversed phase chromatography.Octadecyl phases, 17.5 % C, particle size 3 µm.
From CHF 465.50*

EC analytical columns NUCLEODUR® C18 Isis, 5 µm
C18 phase with special polymeric, crosslinked surface modification - USP L1Pore size 110 ÅHigh steric selectivityOutstanding surface deactivationSuitable for LC/MS due low bleeding characteristicspH stability 1 - 10Broad range of application: steroids, (o,p,m-) substituted aromatics, fat-soluble vitaminsParticle size 5 µm, 20 % C
From CHF 604.80*

HPLC Detector lamps
From CHF 635.00*

EC analytical columns NUCLEODUR® 100-5
Totally spherical high purity silica - USP L3 pore size 110 Å, pore volume 0.9 ml/g, surface (BET) 340 m²/g, density 0.47 g/ml, pressure stability 800 bar, pH stability 2 - 8.Particle size 5 µm.
From CHF 439.40*

EC analytical columns NUCLEODUR® C18 Gravity, 1.8 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 1.8 µm, 18 % C
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 3 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 3 µm, 18 % C.
From CHF 750.90*

EC analytical columns NUCLEODUR® C18 Gravity, 5 µm
NUCLEODUR® C18 - C 8 Gravity nonpolar high density phasesAvailable as octadecyl (C18 -USP L1) and octyl (C8 - USP L7) modifications. Pore size 110 Å.Ideal for method developmentAllows HPLC at pH extremes (pH 1 - 11)Suitable for LC/MS due to low bleeding characteristicsRecommended for overall sophisticated analytical separationsOptimal for: pharmaceuticals, e.g. analgesics, antiinflammatory drugs, antidepressants, herbicides, phytopharmaceuticals, immunosppressantsParticle size 5 µm, 18 % C
From CHF 604.80*