Skip to main content Skip to search Skip to main navigation
Menu

BOD sensor system

Description
Measuring systems for the reliable determination of 90 to 999 ppm BOD. Complete with sensor heads and multi-position magnetic stirrer.
  • The sensor heads are screwed directly onto the BOD bottles
  • Automatic storage of 5 results in 24-hour intervals
  • Measured readings in mg/l (ppm) can be read directly on the sensor at any time
  • Protected against splashing water (IP 54)

Scope of supply BOD sensor system 6: 6-position magnetic stirrer, each 6 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rods
Scope of supply BOD sensor system 10: 10-position magnetic stirrer, each 10 BOD sensors incl. batteries, 500 ml brown glass bottles, KOH reservoirs and magnetic stirring rods


Specifications
BOD range:
90 ... 999 ppm
Display:
LED (3 digits)
IP code:
IP 54
Properties
Description: 6 positions
Manufacturer Article Number: SA10200136
Type: BOD sensor system 6
Type of auxiliary energy: 230 V, 50 ... 60 Hz
Skip product gallery

Accessories

Velp Scientifica SRL

Velp Scientifica SRL
Accessories for BSB/BSB EVO sensor systems
From CHF 16.47*
Skip product gallery

Similar products

Dissolved oxygen bottles, Winkler pattern
Winkler pattern. Soda-lime glass.For determination of dissolved oxygen in water. The measured capacity is specified to ± 0,01ml. With white labelling area. Solid, bevelled glass stopper, secured with an accessory spring clip. Each bottle is adjusted to the relevant stopper. Stoppers and bottles are therefore not interchangeable. Each bottle and its stopper is marked with a unique, matching identification number.
From CHF 34.80*

Thermostatic cabinets TC, with steel door
The incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubatorThe incubators from Lovibond® are designed for continuous tempering for different applications, mainly for the determination of BOD, the storage of wastewater samples, and the determination of enzymatic activity. The temperature range is +2°C up to +40°C and can be regulated in steps of 0,1°C. Temperature tolerance is defined with +/- 1°C respectively +/- 0,5°C (at 20°C). Low engergy consumption due to reinforced isolation. The interior of the cabinets is equipped with sockets for connecting stirrers. Illuminated LED display with actual / setpoint display.Temperature range 2 °C to 40 °C, continuously adjustable in steps of 0.1 °CLow power consumptionIlluminated LED display of preset and current temperaturesWith natural refrigerant R600aIdeal for BOD determination at 20 °CPower sockets inside the incubator
From CHF 2,565.00*

Overflow Measuring Flask for OxiTop®
Glass measuring flask with fixed volume doses for the easy and accurate measurement of the required sample volume for respirometric BSB measurements.
From CHF 68.30*

Adapter AD/SK for BOD measuring system OxiTop®
For OxiTop® measuring heads, for all sample and measuring bottles series PF45/.. and MF45/.., autoclavable (121 °C). Incl. OxiTop® AD adapter, OxiTop® SK screwable adapter, DI45 gasket for adapter VS45.
From CHF 145.00*

Measuring vessels for BOD measuring system OxiTop®
Incl. 1 x DV/MG lid adapter with rack, gasket, 2 x GK 600 rubber sleeves, 4 x DV/MG/KL clamps, 1 x MB 50 measuring beaker (50 ml)
From CHF 358.00*