Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance.

  • Water analysis purely without pH and turbidity measurement for standard parameters

  • Smart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test types

  • Optics: LED's with filters

  • Concentration, Absorption, Transmission

  • Methods can be downloaded from the Internet

  • 50 user defined routines

  • 100 data sets

  • RS 232 interface

Scope of supply: Handheld photometer in field case with table insert, 2 x 2 ml + 10 ml scaled syringes, 16 mm zero cuvette, waterproof quick guide with all programmed test sets, microfibre cloths, LSdata PC software, PC connection cable AK 540/B, screwdriver, 50 ml measuring beaker, 5 x 28 mm cuvettes, batteries, operating manual

Properties
Accuracy: 2 nm
Accuracy: ±2 nm
Battery/rechargeable battery: 4 x 1.5 V, AA
Depth: 236 mm
Designation ANSI: AA
Dimensions (WxDxH): 86 x 236 x 117 mm
Height: 117 mm
IP code: IP 67
Illuminants: LED
Manufacturer Article Number: 251205
Max. voltage battery/rechargeable battery: 1.5 V
No. of batteries/rechargeable batteries: 4
Photometric measuring range: -2.000 ... 2.000, 1 ... 150 %T
Type: pHotoFlex® STD Set
Type of auxiliary energy: Battery/rechargeable battery
Wavelength: 436/517/557/594/610/690 nm
Width: 86 mm
Skip product gallery

Accessories

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test protocols
A: Stored in photoLab® S6, S12, photoLab® 6000 Serie and photoLab® SpektralB: Stored in photoLab® S12, photoLab® 6000 Serie and photoLab® SpektralC: Stored in photoFlex® and photoFlex® Turb®Reagent-free tests:Cu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and UV-VIS photoLab® 6600 (254/436nm)Further tests on demand, range information is based on max. area and can also be smaller for photoFlex®.
From CHF 99.80*

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Serie and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Serie and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for pHotoFlex®.
Price on request

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
LabStation
LabStation with LSdata software for easy data evaluation. The rechargeable battery is included in the delivery.direct export to MS-ExcelGLP-conform data transfercalibration curve calculationadjustment between meter and PC
From CHF 716.00*
Skip product gallery

Other customers also bought

Xylem Analytics Germany (WTW)

Xylem Analytics Germany (WTW)
Handheld photometer pHotoFlex® STD
Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance.Water analysis purely without pH and turbidity measurement for standard parametersSmart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test typesOptics: LED's with filtersConcentration, Absorption, TransmissionMethods can be downloaded from the Internet50 user defined routines100 data setsRS 232 interfaceScope of supply: Handheld photometer, 1 x empty cuvette 16 mm, 2 x empty cuvette 28 mm, batteries, operating manual
From CHF 2,327.00*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Tube tests NANOCOLOR® Copper
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 123.40*

Photometer photoLab® and photoFlex®, stored test programs
A: Stored in photoLab® S6, S12, photoLab® 6000/7000 Series and photoLab® SpectralB: Stored in photoLab® S12, photoLab® 6000/7000 Series and photoLab® SpectralC: Stored in photoFlex® STD, photoFlex® pH and photoFlex® TurbD: Stored in photoLab® 6000/7000 seriesReagent-free tests:COD, Nitrate, Nitrite optical reagent-free measurement in sewage plant outletsCu - copper plating bath, 690nm, 820nm - copper plating bath - BCrO3 - chromium plating bath - chromium plating bath - BNi - nickel plating bath - nickel plating bath - BHZ - Hazen colour - Hazen colour - BIFZ - iodine number, 340nm, 455nm - iodine number - Bm-1 (DFZ) - colouring - FB445 - B, Cm-1 (DFZ) - colouring - FB525 - A, Cm-1 (DFZ) - colouring - FB620 - B, CFAU - turbidity 620 - T620 - BE - extinction - extinction - A, B, CSAK - Spectral absorption coefficient at 254 and 436nm photoLab® 6100 VIS (436nm) and photoLab® 6600 UV-VIS (254/436nm)Further tests and checking aids like standards and reagent solutions for the instruments on demand, range information is based on max. range and can also be smaller for photoFlex®.All stored test sets for the photoLab® and photoFlex® photometers can be found in our online shop.Ordering information for all the articles described above and for other articles can be found online.
From CHF 38.30*

Tube tests NANOCOLOR® Cyanide
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 108.70*

Tube tests NANOCOLOR® Iron
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 99.50*