Photometers MD 100 Boiler Water/Cooling Water

Description
Photometer instruments, specially designed for cooling and boiler water analysis. Thanks to the handy format and the user-friendly indicator chemistry, most of the important parameters can be determined on site. The photometers are supplied pre-calibrated with test methods, simply add the appropriate Lovibond® reagent sets (tablets, powder packs and liquids).
  • Scroll Memory

  • Automatic Switch-Off

  • Real-Time-Clock and Date

  • Calibration Mode

  • Backlit Display

  • Storage Function

  • One Time Zero (OTZ)

  • Waterproof (IP 68)


Scope of supply: instrument in a sturdy plastic case, batteries, 3 glass vials, standard accessories, instruction manual.
Please order reagents separately! Please pay attention that some reagents could be used for Boiler Water or Cooling Water only.

colorpicker

Optics
LEDs, interference filters (IF) and photo sensor in transparent sample chamber
Wavelength Accuracy
± 1 nm
Photometric Accuracy Photometric Resolution
3% FS (T = 20°C - 25°C) 0,01 A
Power Supply
4 micro batteries (AAA), capacity approx. 17 hours or 5000 tests
Auto-Off
automatic switch-off
Display
backlit LCD (on keypress)
Storage
internal ring memory for 16 data sets
Interfaces
infrared interface for test data transfer
Additional Feature
real time clock and date
Calibration
factory calibration and user calibration. Reset to factory calibration possible
Dimensions
155 x 75 x 35 mm (L x W x H)
Weight
basic unit approx. 260 g
Environmental conditions
temperature: 5 - 40 °C, rel. humidity: 30 -90% (non condensing)
Properties
Manufacturer Article Number: 276240
Type: MD 100 Cooling Water
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Accessories NANOCOLOR®
*additional cable required**additional mains adapter required
From CHF 19.20*

Reagents VARIO for Photometer Lovibond®and HACH®
Suitable for Lovibond®Photometers as well as for Photometers of company HACH®**HACH® is a registered trademark of HACH® Company, Loveland, Colorado. Using brand HACH® contains no indication of a connection to this company or to a possible agreement of HACH® Company to composition, examination or suitability for use in spectrophotometers or other equipment or systems, which are sold under the brand HACH®.
From CHF 27.00*

Photometers MD 200
Benchtop devices suitable for mobile use. For precise water control through high-precision optics and high-quality interference filters with long-term stable LEDs as light sources.Automatic shutdownReal time clock and dateAdjustment function displayIlluminated LCD-displayFurther photometer versions available on request.SpecificationsMeasurement cycle:approx. 3 seconds (method dependent)Optics:Temperature compensated LED and photosensor intensifier in a waterproof sample chamberKeyboard:4-key polycarbonate film, splashproofDimensions (W x D x H):110 x 190 x 55 mmWeight:455 gPower supply:4 x AAIP code:IP 68pH:6.5 - 8.4
Price on request

Reagent solutions for photometers Lovibond®
Solution with 15 ml or refill bottle with 100 ml.* Refill bottle
From CHF 16.10*