Skip to main content Skip to search Skip to main navigation
Menu

Waste Water Set-Up MD 610

Description
Flexible wastewater measuring station with mobile photometer MD 610 and thermoreactor RD 125, complete with reagents for COD measurement and the appropriate accessories. With the MD 610, the measurement results of the wastewater can be called up and evaluated on a smartphone or tablet. The RD 125 thermoreactor is equipped with 24 holes for 16 mm cuvettes.
  • Data transfer via Bluetooth® and AquaLX® app
  • Interference filter for increased reproducibility of the results
  • Memory for 500 measurement results
  • 120 pre-programmed methods

Scope of supply: Photometer MD 610, standard accessories, Thermoreactor RD 125, Cuvette tests: COD (0 ... 150 mg/l, 0 ... 1500 mg/l, ammonium VARIO HR (1 ... 50 mg/l N), nitrate VARIO (1 ... 30 mg/l N), nitrite LR VARIO Powder Pack (0.01 ... 0.3 mg/l N), nitrogen VARIO Total HR (5 ... 150 mg/l N ), phosphate VARIO Total HR (0.02 ... 1 mg/l P / 0.06 ... 3.5 mg/l PO4), cuvette stand, membrane filtration set, operating instructions, warranty declaration

Hazardous Substance Data
GHS
colorpickercolorpickercolorpickercolorpickercolorpickercolorpickercolorpicker
Signal word
Gefahr
H-Satz
H272, H302, H315, H319, H334, H317, H335, H318, EUH031, H290, H314, H412, H410, H340, H350, H311, H373, H302+H332
P-Satz
P261, P280, P301+P312, P302+P352, P305+P351+P338, P342+P311, P310, P501, P260, P301+P330+P331, P303+P361+P353, P304+P340, P301+P312, P337+P313, P234, P308+P313, P390, P405, P308+P310
UNNR
3316
SDS
Link
Properties
GHS: GHS03, GHS07, GHS08, GHS05, GHS06, GHS03, GHS09
Manufacturer Article Number: 214110
Type: MD 610
Skip product gallery

Zubehör

Tintometer GmbH

Tintometer GmbH
Thermoreactor RD 125
Chemical digestion of samples is required for the photometric determination of COD, TOC, total chromium, total phosphate and total nitrogen. The required temperatures and reaction time can be selected by using the membrane keypad of the reactor RD 125. The unit works at three different temperatures (100 / 120 / 150 °C) and three pre-set reaction times (30 / 60 / 120 minutes). When digestion is complete, the reactor automatically switches off and gives a corresponding LED indication with short beep alarm. The RD 125 reactor is fitted with 24 holes for 16 mm diameter vials.SpecificationsPower supply:230 V / 50-60 Hz or 115 V / 50-60 Hz (switchable)Power:550 WDimensions:248 x 219 x 171 mmWeight:3.9 kgHoles in the aluminium block:24 holes, 16.2 mm ± 0.2 mmSelectable temp.:100 / 120 / 150 °CSelected time:30 / 60 / 120 / min. and continuous operation (∞)Heating up:from 20°C to 150°C in 12 min.Protection against overheatingBeeperEnvironmental conditions:10 - 40 °C max. 85 % rel. humidity
From CHF 1,339.00*
New

Tintometer GmbH

Tintometer GmbH
Photometer-System MD 610
Moderne, tragbare Photometer für die schnelle, zuverlässige AnalyseDie Geräte decken alle wichtigen Parameter der Wasseranalytik ab, von Aluminium bis Zink. Hohe Genauigkeit der Lovibond® Reagenzien und einfache Handhabung der Geräte garantieren eine zuverlässige und schnelle Analyse ihrer Wasserproben. Zum Einsatz kommen je nach Methode Reagenztabletten, Pulverreagenzien, Flüssigreagenzien oder Küvettentests. Diese müssen separat bestellt werden.Sechs langzeitstabile LEDs als Lichtquelle in Kombination mit Interferenzfiltern garantieren höchste Genauigkeit. Die Geräte kommen ohne bewegliche Teile in der Optik aus und haben daher eine wartungsfreie Messeinheit.Höchste reproduzierbare Genauigkeit durch InterferenzfilterHintergrundbeleuchtetes DisplayMehr als 120 vorprogrammierte MethodenAutomatische Auswahl der WellenlängeBenutzerführung in Deutsch, Englisch, Französisch, Spanisch, Italienisch, Portugiesisch, PolnischMehr als 35 anwenderspezifische Methoden möglichWasserdichtes Gehäuse (analog IP 67)Handliches Format, tragbarSpeicher für bis zu 500 DatensätzeBluetooth® Schnittstelle zur Verbindung mit Smartphones und TabletsKostenlose iOS®- und Android™-App für Datenmanagement und E-MailversandLieferumfang: Das Gerät wird komplett und gebrauchsfertig im Kunststoffkoffer geliefert, inkl. 4 Batterien, 3 Küvetten 24 mm Ø, 3 Küvetten 16 mm Ø, je 1 Adapter für 16 mm und 13 mm Küvetten, Certificate of Compliance.Reagenzien bitte separat bestellen.
From CHF 1,772.00*
Skip product gallery

Similar products

Tube tests NANOCOLOR® Sulfide / Sulfite / Sulfate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 107.20*

Tube tests NANOCOLOR® ortho- and total Phosphate
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.
From CHF 133.40*

Tube tests NANOCOLOR® COD
A maximum in accuracy and precision is granted for the measurement results due to exactly pre-dosed reagents in 16 mm cuvettes and additional reagents. The tests are pre-programmed in photometers and selected automatically via a barcode on the cuvette. The contact with any dangerous chemicals is avoided because the measurement is performed directly in the test tube. This guarantees maximum safety for the user.DIN ISO 15705
From CHF 114.60*

Accessories NANOCOLOR®
*additional cable required**additional mains adapter required
From CHF 19.20*

Digestion Reagents for Photometer photoLab® and pHotoFlex®
For water analysis and electric plating to capture total nitrogen and heavy metals besides COD, total phosphorus.Comfortable with reagent presentation in round cuvettesQuick preparation of digestion
From CHF 164.00*

Cells for Photometer photoLab®
Cuvettes for photometric routine and water analytics in the UV-VIS and VIS range. Cells with matt side surface are suitable for the automatic cell detection of the photoLab® filter and spectral photometer. The glass and quartz cuvettes have a marking in order to place the cuvettes into the photometer in the same direction for an even higher precision.Automatic cell detectionGlass and quartz cells with marking for higher precisionHigh quality optical glass for VISHigh quality quartz glas for UV-VIS
From CHF 95.20*

Photometer system MultiDirect
With Dual Beam Technology. The MultiDirect is a modern, microprocessor-controlled photometer with ergonomically designed keypad and large-format graphic display. It is equipped with a wide range of pre-programmed methods (e.g. ammonia, COD, phosphate) based on the proven range of Lovibond® tablet reagents, liquid reagents, vial tests and powder reagents. The calibration and software-supported control options mean that the unit is also suitable for use as a testing instrument. The seven standard rechargeable batteries (supplied) ensure easy mobile use.Wide range of pre-programmed methodsLarge, graphics displayRS232 interfaceSuitable for use with standard rechargeable batteriesUpdates for new methods and languages via the Internet1000 data set memoryCustom method recall is also possibleScope of supply: MultiDirect, ready-to-use incl. 7 x rechargeable batteries and battery charger for 100 - 240V, 3 each 24mm and 16mm cuvettes, 16mm cuvette adapter, 3 x syringes, 1 x 100ml plastic beaker and case with waterproof insert. Without reagents and without battery (please order separately).Verification Standard Kit: The verification standard kit for the MultiDirect is designed to reassure the user about the accuracy and the reliability of the results. The shelf life of the standard kit is two years from the date of production, provided that storage and use are in accordance with the instructions provided. Measurements are taken in mAbs.Specifications Optics: Dual-Beam Technology, High-quality Interference FiltersMeasuring time: Power supply:approx. 10 seconds 7 Ni-MH-battery pack (1.5V AA), charged in the unit using external power packDimensions (W x D x H): Ambient operating conditions: Approval:265mm x 70mm x 195mm up to max 90 % humidity (non condensing), approx. 5 ... 40 °C CEWavelengths:430/ 530/ 560/ 580/ 610/ 660nm
From CHF 2,064.00*

Handheld photometer pHotoFlex® pH Field case set
Handheld photometers for use in a wide range of areas such as process control, mobile water testing or wine industry. Easy operation with menu driven, user guidance. Just like the standard version of pHotoFlex® STD plus full electrochemical pH-and ORP measurement via electrodes. This allows also the measurement of the parameters NH3 and CO2.pH 0 to 16.00 (±0.01) for Standard-DIN pH-electrodes with automatic temperature compensation ATC and automatic buffer recognitionSmart cuvette adapter: holds 28 mm or 16 mm round cuvettes with height 91 to 104 mm; to be used with a variety of different test typesOptics: LED's with filtersConcentration, Absorption, TransmissionMethods can be downloaded from the Internet100 user defined routines1000 data setsRS 232 interface1 to 3 point calibrationIncl. calibration interval and calibration protocolScope of supply: Handheld photometer in field case with table insert, 0.500 to 5 ml pipette, pH electrode SenTix® 41, technical buffer solution 7.00 and 4.01, 50 ml KCl, 16 mm zero cuvette, waterproof quick guide with all programmed test sets, microfibre cloths, LSdata PC software, PC connection cable AK 540/B, screwdriver, 50 ml measuring beaker, 5 x 28 mm cuvettes, batteries, operating manual
From CHF 4,131.00*